Skip to content

Integrated robot joint actuator

Unitree Bionic joint motor IM6014 (N6014B) integrated robot joint actuator

Bionic robot joint motor with about 12.66:1 reduction, up to 34.4 Nm peak torque, 24–75 V input, dual absolute encoders (rotor and output) and RS-485 multidrop at up to 6 Mbps.

Need this part, a replacement or a better-fit option? Our engineers help with selection, procurement, sourcing, competitive pricing and lead times.

Engineering support · Product sourcing · Procurement

Get pricing or a checked replacement

Need Unitree parts, a replacement or another suitable option? Send your part number or describe the application. We’ll review the requirement and help with product selection, sourcing, pricing and lead times.

  • Exact parts and engineer-checked alternatives
  • Manufacturer-direct options where available
  • Standard, modified and custom solutions

No obligation to buy. Have a datasheet, drawing or nameplate photo? Reply to your confirmation email to attach it.

Need help choosing? Build a specification →
Add quantity, timing or application notes (optional)
Need help choosing? Open the specification builder

Spec builder

Specify what you need instead of Bionic joint motor IM6014 (N6014B)

Select every part you need, answer the questions an applications engineer would ask, and see your summary before we ask for any details.

  1. 1Products
  2. 2Performance
  3. 3Environment
  4. 4Volumes
  5. 5Your spec
Step 1 of 5

Key specifications

Voltage (max)75 V
Data / busRS-485 multidrop (4 or 6 Mbps)
Peak torque (max)34.4 Nm
Speed (max)517 rpm
Supply24–75 V
Ratio (max)12.66:1
Weight535 g
Encoderdual absolute encoders, 15-bit rotor side

Summarised in our own words from Unitree Robotics (Yushu Technology Co., Ltd.)'s published data; series maxima, individual models vary. Last checked 2026-10-30. Source 1

Notes on this data

Ratio listed inconsistently on the page; the model name N6014B-12.6 and FOC chart indicate about 12.66:1.

Specify Motion is not affiliated with Unitree Robotics (Yushu Technology Co., Ltd.). Unitree and Bionic joint motor IM6014 (N6014B) are used only to identify the product. Comparisons use published figures; always confirm against the current datasheet.

Unitree Bionic joint motor IM6014 (N6014B) replacement and alternative options

Use these supply-network options as a starting point for an engineering check. We can also help source the original Unitree part. Published series figures do not establish an exact-model or drop-in replacement: confirm ratings, fit, interfaces and approvals for your application.

Planetary gearbox

Wanshsin WSH

Limited published data: 2 figures compared

High-rigidity Wanshsin inline planetary with three backlash classes down to super-precision, for machine tools, automation and AGVs.

Published maximumBionic joint motor IM6014 (N6014B)WSH
Peak torque34.4 Nm7,200 Nm meets or exceeds
Rated torque—2,400 Nm
Speed517 rpm6,000 rpm meets or exceeds
Spiral bevel gearbox

Wanshsin WSHR

Limited published data: 2 figures compared

Right-angle version of the high-rigidity WSH, with a spiral bevel stage and ratios up to 200:1.

Published maximumBionic joint motor IM6014 (N6014B)WSHR
Peak torque34.4 Nm4,200 Nm meets or exceeds
Rated torque—1,400 Nm
Speed517 rpm6,000 rpm meets or exceeds
Planetary gearbox

Wanshsin WTH

Limited published data: 2 figures compared

Wanshsin inline planetary designed for high radial loads, offered in three precision classes.

Published maximumBionic joint motor IM6014 (N6014B)WTH
Peak torque34.4 Nm6,150 Nm meets or exceeds
Rated torque—2,050 Nm
Speed517 rpm6,000 rpm meets or exceeds

Figures are the highest published for each series and are not always measured the same way. A higher figure is not automatically a better choice: mounting, duty cycle, feedback, connectors and approvals matter too. An engineer will check the fit against your application before recommending anything.

Typical applications

Humanoid and legged robot joints

What an integrated robot joint actuator is

An integrated robot joint actuator packages a brushless motor, a reduction gear, encoders, a servo drive and often a brake or torque sensor into one module that bolts in as a robot joint. Gearing may be planetary, strain-wave or cycloidal. Many are designed for legged robots, humanoids and cobots, with low gear ratios or quasi-direct drive to keep the joint back-drivable and responsive. Communication is typically over CAN or EtherCAT, with position, velocity and torque control modes.

When engineers choose an integrated robot joint actuator

Choose an integrated joint actuator to build robots faster with fewer parts, especially legged, humanoid, exoskeleton and collaborative robots. Back-drivable versions suit force control and impacts. The trade-offs are torque density, precision and industrial qualification: low-ratio designs trade output torque for transparency, and some units are aimed at research rather than production duty. For industrial arms with heavy duty cycles, a dedicated harmonic actuator or motor and gear set may be better.

How to specify the Unitree Bionic joint motor IM6014 (N6014B)

Send these with your enquiry and an engineer can confirm the right Bionic joint motor IM6014 (N6014B) variant or an equivalent:

  • Peak and continuous output torque (Nm)
  • Output speed (rpm)
  • Gear type and ratio
  • Back-drivability and torque sensing
  • Supply voltage (V DC)
  • Communication interface and control modes
  • Mass and size (kg, mm)

Common mistakes to avoid

  • Using peak torque as continuous torque
  • Ignoring thermal limits in legged robots
  • Overlooking bus bandwidth with many joints
  • Assuming research-grade units meet industrial life requirements

Unitree Bionic joint motor IM6014 (N6014B): frequently asked questions

Can you help replace Unitree Bionic joint motor IM6014 (N6014B) or source the original?

Send the full model code, quantity and required date. Our engineers can check original-part availability and assess suitable alternatives, including Motion Control Products options where appropriate. We confirm compatibility and any changes needed before recommending a replacement.

What is the Unitree Bionic joint motor IM6014 (N6014B)?

Bionic robot joint motor with about 12.66:1 reduction, up to 34.4 Nm peak torque, 24–75 V input, dual absolute encoders (rotor and output) and RS-485 multidrop at up to 6 Mbps. Published series figures include voltage 75 V, peak torque 34.4 Nm, speed 517 rpm, ratio 12.66:1. It is made by Unitree Robotics (Yushu Technology Co., Ltd.); Specify Motion can help source it or propose an equivalent.

Who makes the Unitree Bionic joint motor IM6014 (N6014B)?

The Unitree Bionic joint motor IM6014 (N6014B) is made by Unitree (Unitree Robotics (Yushu Technology Co., Ltd.)) and is listed here for engineers comparing options. Specify Motion is not affiliated with Unitree Robotics (Yushu Technology Co., Ltd.); brand names are used only to identify the product.

What is the voltage of the Unitree Bionic joint motor IM6014 (N6014B)?

The published series maximum voltage is 75 V. Individual models and sizes in the Bionic joint motor IM6014 (N6014B) range vary, so check the exact variant against your duty cycle, mounting and environment, or ask our engineers to confirm the right size for you.

Is there an alternative to the Unitree Bionic joint motor IM6014 (N6014B)?

We can assess suitable replacement options. On published figures, Wanshsin WSH and Wanshsin WSHR are options to assess from our supply network. An engineer confirms the fit against your application before recommending anything.

What is a quasi-direct-drive actuator?

A quasi-direct-drive actuator uses a high-torque motor with a low gear ratio, typically below about 10:1, so the joint is back-drivable and responds quickly to external forces. This suits legged robots and force control. The trade-off is lower output torque than high-ratio joints of similar size.

Why integrate the drive in a robot joint actuator?

Integrating the drive reduces cabling and lets each joint communicate over a shared bus, which simplifies robot design. It also allows the drive to sit close to the motor, improving control. The trade-off is that heat from both motor and drive must be managed inside the joint.

Further reading: How to select a harmonic actuator · Frameless motor sizing robot joints · Gearboxes and harmonic drives

Other integrated robot joint actuator series

Engineer support

Let our experienced engineers do the hard work for you

Tell us how you use the Unitree Bionic joint motor IM6014 (N6014B): the load, speed, duty and environment. Our engineers will confirm whether it is still the right part, find it for you, or propose an alternative that fits better.

  • Reviewed by an engineer, not an autoresponder
  • Like-for-like and better-fit alternatives
  • Standard, modified and custom options

Prefer to configure it? Use the spec builder.

We use your details to answer this enquiry and share them with the specialist engineering and supply partner best placed to fulfil it. See our privacy notice.