Key specifications
| Ingress protection | IP65 standard; IP67 (static) option (not IMA22) |
|---|---|
| Temperature | 10–40 °C |
| Force (max) | 30,600 N |
| Continuous force | 13,130 N |
| Stroke (max) | 457 mm |
| Linear speed (max) | 1,334 mm/s |
| Screw lead | 4, 5, 10, 20, 25 |
| Screw type | ball or planetary roller |
| Backlash | ball 0.1; roller 0.051 |
| Supply | 230 or 460 VAC |
| Duty | not stated (RMS thrust/speed method) |
| Sizes | IMA22, IMA33, IMA44, IMA55 |
| Lead accuracy | ball ±0.051 mm/300 mm; roller ±0.010 mm/300 mm |
| Temp extended | -20 to 60 °C on request |
Series ranges as published; individual models vary. The full datasheet, drawings and CAD models are available on request.
Options
- incremental, Hiperface, Hiperface DSL, EnDat 2.2 or resolver feedback
- connectors for Rexroth, Nidec, Lenze, Siemens, Allen Bradley drives
- 24 V holding brake
- anti-rotate (ARO)
- side, plate, flange, trunnion, clevis mounts
- rod-end options
- food-grade grease
- white epoxy (food) or black (heavy duty) finish
Typical applications
Often compared with
Engineers specifying this series often compare it with:
Spec builder
Configure Tolomatic IMA Integrated Motor Actuator
Select every part you need, answer the questions an applications engineer would ask, and see your summary before we ask for any details.
- 1Products
- 2Performance
- 3Environment
- 4Volumes
- 5Your spec
Engineer support
Need Tolomatic IMA Integrated Motor Actuator or a complete system around it?
Tell us what you need, whether it is this part, an equivalent or a complete axis built around it. An engineer will review your requirements and reply, normally within one working day.
- Reviewed by an engineer, not an autoresponder
- Like-for-like and better-fit alternatives
- Standard, modified and custom options
Prefer to configure it? Use the spec builder.